Electric in wall splice kit9/27/2023 Where connections to conductors are by binding-screw terminals, there shall be available as many terminals as conductors. Openings in such devices shall form a close fit around the outer covering of the cable, and the device shall fully enclose the part of the cable from which any part of the covering has been removed. Switch, outlet, and tap devices of insulating material shall be permitted to be used without boxes in exposed cable wiring and for rewiring in existing buildings where the cable is concealed and fished. NEC 334.40(B) Devices of Insulating Material. NEC approved Article 334-40b.įor Use On 12 or 14 AWG (300 Volt) 2 wire NM cable with ground Splice and Tap Kits also eliminate wire nuts for installation and replace the conventional method for adding a splice or tap for non-metallic cable without the need for exposed and unsightly junction boxes. They are designed and approved for use in rework within existing structures. Tyco Electronic's Non-metallic splice and tap kits provide a fast and reliable method for splicing or tapping 2 wire w/ ground and splicing 3 wire w/ground non-metallic cables up to 300 volts. (Model # CPGI-1116377-2.) They say the following: The big box stores in the US sell something called the Tyco Electronics Romex splice kit. If I'm completely misunderstanding, please point it out, so that I and others might learn. I'm putting this up as an answer, mostly because there wasn't enough space in the comments.